1. PAINPOINT DRIVEN OPENING Managing the final stage of clinker cooling is a critical bottleneck with direct consequences for plant profitability. Inefficient clinker cooler operation leads to excessive heat loss, reducing thermal recovery for your preheater and calciner systems. Unstable cooling results in clinker quality inconsistencies, causing downstream grinding inefficiencies and potential cement performance issues.…


پيداوار جي تفصيل

پراڊڪٽ ٽيگ

1. PAINPOINT driven اوپننگ

Managing the final stage of clinker cooling is a critical bottleneck with direct consequences for plant profitability. Inefficient clinker cooler operation leads to excessive heat loss, reducing thermal recovery for your preheater and calciner systems. Unstable cooling results in clinker quality inconsistencies, causing downstream grinding inefficiencies and potential cement performance issues. Frequent maintenance interventions for grates, هائيڊولڪس, and fans create unplanned downtime, while highpressure fans drive significant electrical energy consumption. ڇا توهان في ٽين ڪلينڪر جي وڌندڙ توانائي جي قيمت کي منهن ڏئي رهيا آهيو? Is your cooler refractory and mechanical component lifespan shorter than expected? The solution lies in optimizing this essential link between the kiln and the finish mill.

2. پيداوار جو جائزو: Grate Clinker Cooler

The Grate Clinker Cooler is a critical heat recovery and conditioning machine installed directly after the rotary kiln discharge. Its primary function is to rapidly reduce clinker temperature from approximately 1200°C to below 100°C for safe handling and storage, while simultaneously recovering and supplying hot air to the kiln and calciner.

آپريشنل ڪم فلو:
1. Inlet & ورهائڻ: Redhot clinker from the kiln enters via an inlet hopper and is evenly distributed across the full width of the stationary inlet grate.
2. Grate Transport & Primary Cooling: Reciprocating grates convey the clinker bed forward. Highpressure cooling air is forced upward through the grate plates and clinker layer, providing intensive quenching.
3. گرمي جي بحالي: A significant portion of the heated cooling air is directed as secondary air to the kiln combustion zone and as tertiary air to the calciner, directly improving kiln fuel efficiency.
4. فائنل کولنگ & خارج ٿيڻ: The clinker moves through subsequent grate zones with controlled air volumes for final cooling before being discharged via a drag chain or roller crusher at the cooler outlet.

ايپليڪيشن جو دائرو & حدون:
دائرو: Designed for dryprocess cement plants with rotary kilns, suitable for capacities from 1,500 ختم ڪرڻ 12,000 ٽي پي ڊي. Effective for a wide range of raw mix compositions.
حدون: Performance is highly dependent on consistent clinker granulometry; extreme variations can lead to uneven air distribution (piping). Not designed for wet process kilns or as a standalone unit without integrated heat recovery ducting.

3. بنيادي خاصيتون

ماڊل گريٽ پليٽ سسٽم | ٽيڪنيڪل بنياد: Highchromium cast alloy design with optimized aperture geometry | آپريشنل فائدا: حرارتي جھٽڪو ۽ گھڙڻ لاء غير معمولي مزاحمت, leading to plate lifetimes exceeding 5 years under normal conditions | ROI اثر: تائين گھٽائي ٿو اسپيئر پارٽس جي انوینٽري جي قيمت تائين 30% and major maintenance downtime intervals.

Adaptive Air Flow Control | ٽيڪنيڪل بنياد: Multiple independently controlled fan zones with PLCmanaged dampers | آپريشنل فائدا: Allows precise air volume adjustment per cooling zone based on realtime clinker bed conditions and temperature feedback | ROI اثر: پاران گرمي جي بحالي جي ڪارڪردگي کي بهتر بڻائي ٿو 35%, directly reducing specific fuel consumption.

Hydraulic Reciprocating Drive | ٽيڪنيڪل بنياد: Electrohydraulic drive system with proportional valves for smooth motion control | آپريشنل فائدا: Provides infinitely variable stroke length and speed, enabling optimal clinker bed movement without turbulence or dust generation | ROI اثر: Enhives cooler stability, reduces electrical consumption of drive system by up to 15% مقرر رفتار سسٽم جي مقابلي ۾.

Advanced Sealing System | ٽيڪنيڪل بنياد: Labyrinth seals combined with pressurized sealing air chambers at grate edges | آپريشنل فائدا: Minimizes false air infiltration into the hot air recuperation ducts | ROI اثر: Increases secondary/tertiary air temperature by an average of 2030°C, improving overall kiln system thermal efficiency.

مربوط حالتن جي نگراني | ٽيڪنيڪل بنياد: Thermocouples embedded in grate plates and bearing sensors on fan motors | آپريشنل فائدا: Provides early warning of potential failures like red rivers or mechanical issues through centralized control room alerts | ROI اثر: اڳڪٿي واري سار سنڀال جي شيڊول کي فعال ڪري ٿو, preventing catastrophic failures that can cause 714 days of production loss.

4. مقابلي جا فائدا

| ڪارڪردگي ميٽرڪ | انڊسٽري معياري معيار | Our Grate Clinker Cooler Solution | فائدو (% سڌارو) |
| : | : | : | : |
| Specific Cooling Air Volume (Nm³/kgcli) | ~2.0 2.2 Nm³/kgcli| ≤1.8 Nm³/kgcli| تائين 10% گهٽتائي |
| گرمي جي بحالي جي ڪارڪردگي (%)| ~70 72%| >74%| ~ 35٪ واڌارو |
| گريٽ پليٽ سروس جي زندگي (مهينا) | ~36 48 مهينا| >60 مهينا| ~25% longer lifespan |
| برقي توانائي جو استعمال (kWh/tcli) | ~ 6 7 kWh/tcli| ~5 5.5 kWh/tcli| تائين 15% گهٽتائي |
| ڪلنڪر آئوٽليٽ جي درجه حرارت (°C) Ambient +80100°C| Ambient +65°C max.| More consistent grindability |

5. ٽيڪنيڪل وضاحتون

گنجائش جي حد: کان ترتيب ڏئي سگهجي ٿو 2,500 جي طرف 10,000 ٽين في ڏينهن (ٽي پي ڊي) ڪلينر جو.
بجلي جي گهرج: Total connected load varies by size; مثال, هڪ 5,000 TPD cooler requires approximately 8001000 kW for all fans and drives (3مرحلو, وولٹیج پلانٽ جي وضاحت جي مطابق).
مواد جي وضاحت: Grate plates cast in ZCr26Ni12 highchromium alloy; side liners in abrasionresistant steel; housing constructed from carbon steel with internal refractory lining in hot zones.
جسماني طول و عرض (Example for 5k TPD): Overall length ~35m; ويڪر ~ 6m; height from ground level ~10m.
ماحولياتي آپريٽنگ رينج: 20 ° C کان + 50 ° C تائين محيطي درجه حرارت لاء ٺهيل; dustladen environment compatible.

6. درخواست جا منظر

Plant Capacity Upgrade Challenge Challenge A midsized plant increased kiln capacity by 20%, but the existing cooler became a bottleneck, causing high outlet temperatures and reduced kiln efficiency. Solution Implementation A retrofit involved installing wider modular grate sections,a new highefficiency hydraulic drive,and upgraded highpressure fans. Results Quantifiable Outcomes Clinker throughput matched new kiln capacity.outlet temperature stabilized below+75°C,and secondary air temperature increased by45°C,saving1$5%in specific fuel consumption

High Maintenance Cost Scenario Challenge A plant faced annual downtime exceeding300 hours due to frequent grate plate changesand seal failures on an older cooler model. Solution Implementation Replacement with our modular grate system featuringthe advanced sealing technologyand integrated condition monitoring package. Results Quantifiable Outcomes Grate plate replacement interval extendedfrom18to54 months.Predictive monitoring reduced unplanned stopsby80%.Total annual maintenance hours relatedto the cooler fell by over60%

7 تجارتي خيالاتCommercial Cement Plant Equipment Maker

سامان جي قيمت ظرفيت تي ٻڌل آهي(ٽي پي ڊي)and specific configuration requirements:
Base Configuration Tier Includes core cooler structure,grate modulesstandard drives,and basic control integration
Optional Features Available upgrades include advanced process control software packageshighefficiency fan impellers,and premium instrumentation suites
Service Packages We offer structured plansfrom annual inspectionand parts kits too comprehensive longterm service agreements(LTSAs)covering all mechanicaland electrical components
Financing Options Flexible capital expenditure solutions are available including traditional purchase equipment leasingand performancelinked financing structures where payments can be partially alignedwith verified efficiency gains

8 FAQCommercial Cement Plant Equipment Maker

Q What levelof modificationis requiredto retrofit this coolerto an existingkiln line?
A Retrofit engineeringis a core competency.The interface at the kiln hoodis carefully designedto match existing geometry Minimal disruptionto foundation structuresis targetedwith most work occurringduring planned major kiln shutdowns

Q How doesthe adaptive airflowcontrol impactoperator workload?
A The system operatesautomaticallybasedon set parametersand feedbackloops reducingthe needfor manual damper adjustmentsby operators This allows personnelto focuson monitoringoverall system healthratherthan constant tuning

Q Are spare parts forgrate plates standardizedor custom?
A We utilizea modular designwith standardizedinterchangeableplate sizeswithin eachcooler model This drastically simplifiesinventory managementfor plantsand ensuresglobal availabilityof critical wear parts

Q Whatisthe typicalinstallationand commissioningtimelinefor anew greenfieldcooler?
A Fora full greenfield installationmechanical erectionrequiresapproximately1620 weeksfollowing foundation readiness Electricaland automation integrationadds46 weeks Commissioningand performance guaranteetesting typically takes34 weeks

Q Do you provideperformance guarantees?
A Yes we offer contractual guaranteeson key metricsincluding specificair volumeclinker outlet temperature heat recovery efficiencyand total power consumption subjectto agreedupon baseline conditions