Spécifications du producteur d'équipement de cimenterie

Brève description:

Cibler les directeurs d'usine & Entrepreneurs en ingénierie: Optimizing Clinker Cooling for Peak Kiln Efficiency Are your kiln output and plant profitability limited by inefficient clinker cooling? Inconsistent cooling rates directly impact grindability, increasing specific power consumption in the finish mill by 815%. Excessive cooler air leakage not only wastes energy but can lead to thermal shock…


Détail du produit

Mots clés du produit

Cibler les directeurs d'usine & Entrepreneurs en ingénierie: Optimizing Clinker Cooling for Peak Kiln Efficiency

Are your kiln output and plant profitability limited by inefficient clinker cooling? Inconsistent cooling rates directly impact grindability, increasing specific power consumption in the finish mill by 815%. Excessive cooler air leakage not only wastes energy but can lead to thermal shock and reduced refractory life in the kiln discharge zone. En outre, unreliable grate plate systems cause frequent, unplanned shutdowns for maintenance, coûtant en moyenne 1824 hours of lost production per incident. Are you managing high maintenance costs from abrasive clinker wear and struggling to meet increasingly stringent emission targets due to nonoptimized air flows? Le droit rotary clinker cooler is not just a heat exchanger; it is a critical determinant of your plant's thermal efficiency, equipment longevity, and operating cost structure.

Présentation du produit: HighEfficiency Rotary Clinker Cooler

Ce rotary clinker cooler est un robuste, cylindrical heat recovery unit installed at the discharge end of the cement kiln. Its primary function is to reduce clinker temperature from approximately 1200°C to below 100°C for handling while recovering and redirecting hot secondary air back to the kiln and tertiary air to the calciner.

Flux de travail opérationnel:
1. Infeed & Distribution: Incandescent clinker from the kiln discharges onto internal lifting flights within the rotating shell.
2. CounterCurrent Heat Exchange: Pendant que la coquille tourne, clinker is lifted and cascaded through a controlled flow of ambient cooling air introduced at the discharge end.
3. Controlled Residence Time: The rotation speed and internal flight design govern material travel time, ensuring precise cooling.
4. Récupération de chaleur: Hot air exiting the cooler (secondary/tertiary air) is channeled back to combustion processes.
5. Décharge: Cooled clinker exits via a sealed outlet for conveyance to storage.

Champ d'application: Ideal for medium to large capacity cement production lines with rotary kilns. This technology is particularly effective where consistent clinker quality and maximized heat recovery are priorities.
Limites: Requires stable kiln operation for optimal performance; not typically suited for very small plants or those using nonrotary kiln technologies.

Fonctionnalités principales: Conçu pour la fiabilité & Retour sur investissement

Advanced Lifting Flight Design | Base technique: Optimized cascade profile based on granular material dynamics | Avantage opérationnel: Creates a uniform curtain of clinker for maximum gassolid contact and even cooling | Impact sur le retour sur investissement: Improves heat recovery efficiency by up to 72%, reducing specific fuel consumption.

Système de plaques de grille modulaire | Base technique: Highchrome, abrasionresistant alloy castings with bolted assembly | Avantage opérationnel: Allows for individual plate replacement during scheduled maintenance, minimiser les temps d'arrêt | Impact sur le retour sur investissement: Cuts coolerrelated maintenance downtime by an estimated 40% annuellement.

Système d'entraînement hydrostatique | Base technique: Multimotor girth gear drive with variable frequency control | Avantage opérationnel: Fournit une douceur, reliable rotation with precise speed control under varying loads | Impact sur le retour sur investissement: Enhances drive train longevity, reducing major drive system overhaul costs over a 10year lifecycle.

Enhanced Sealing Solutions | Base technique: Multistage labyrinth seals combined with pneumatic sealing at inlet/outlet | Avantage opérationnel: Dramatically reduces false air infiltration (to below 10% of total airflow) | Impact sur le retour sur investissement: Improves kiln combustion efficiency and can reduce ID fan power draw.

Intelligent Cooling Air Control | Base technique: Segmented plenum chambers with independently adjustable fans | Avantage opérationnel: Enables zonebased cooling control to match clinker bed conditions and temperature profile | Impact sur le retour sur investissement: Optimizes power consumption of cooler fans and improves final clinker quality.

Predictive Maintenance Integration | Base technique: Standardized ports for thermal imaging, surveillance des vibrations, and condition sensors | Avantage opérationnel: Facilitates realtime health monitoring of bearings, lecteurs, and shell integrity | Impact sur le retour sur investissement: Transforme la maintenance de réactive en prédictive, avoiding catastrophic failure.

Avantages compétitifs

| Mesure de performances | Norme de l'industrie (Reciprocating Grate Cooler) | Our Rotary Clinker Cooler Solution | Avantage (% Amélioration) |
| : | : | : | : |
| Efficacité de récupération de chaleur | ~6570% typical recovery rate| Cohérent >72% recovery rate demonstrated| +37% improvement in thermal efficiency |
| Consommation d'énergie spécifique| Higher due to grate movement & numerous fans| Inférieur; driven only by rotation & fewer fans| Jusqu'à 15% reduction in cooler fan power |
| Temps d'arrêt pour maintenance (Annuel)| 80120 hours for grate replacement & general upkeep| 4060 hours focused on inspection & minor parts| ~50% reduction in annual downtime |
| False Air Infiltration| Typiquement 1525% of total cooling airflow| Maintient 50% reduction in wasted fan energy |
| Clinker Temperature Outlet| Can be variable (+/ 50°C) with uneven grates| Cohérent (+/ 15°C) due to tumbling action| Improved grindability & mill output |

Spécifications techniques

Spécifications du producteur d'équipement de cimenterie

Plage de capacité: Designed for kiln outputs from 2,000 DPT à 8,000 DPT.
Exigences d'alimentation: Moteur d'entraînement principal(s): 150400 kW (selon la taille). Cooling fan total installed power varies with configuration.
Spécifications matérielles: Coque construite à partir de tôles d'acier au carbone; Internal lifting flights made from heatresistant cast steel; Inlet section lined with refractory castables.
Dimensions physiques (Sample for 3,500 DPT): Diamètre de la coque: 4.2m; Shell length: 28m; Total installed weight (env.): 450 tonnes.
Plage de fonctionnement environnementale: Conçu pour des températures ambiantes de 20°C à +45°C. Dusttight construction suitable for outdoor installation.

Scénarios d'application

Modernization of Integrated Cement Plant

Défi: A plant in Southeast Asia operated an aging grate cooler suffering from high air leakage (>22%) and frequent grate plate failures, limiting kiln output and increasing fuel costs.
Solution: Replacement with a customengineered rotary clinker cooler, including an integrated hydraulic drive and upgraded instrumentation.
Résultats: Secondary air temperature increased by approximately 85°C. Kiln specific fuel consumption decreased by over 3%. Annual maintenance hours on the cooler system were reduced by nearly 300 hours within the first year.

Expansion Project for Growing Producer

Défi: An engineering contractor required a reliable cooling solution for a new production line where space was constrained and operational simplicity was valued over complex mechanical systems.
Solution: Installation of a single rotary clinner cooler as part of the greenfield plant design.
Résultats: The simpler layout reduced civil costs. The robust design allowed plant operators to achieve stable operation faster during commissioning. Field data shows the unit has consistently met guaranteed capacity and outlet temperature specifications since startup.

Considérations commerciales

Niveaux de tarification: Capital cost varies significantly with capacity:
Niveau I (6,000 DPT): Fully customengineered solutions.
Fonctionnalités facultatives: Advanced process control package (Intégration automate/SCADA), supplemental water spray system for extreme conditions, extended warranty on drive components.
Forfaits de services: Choose from annual inspection packages, fullservice maintenance contracts including parts inventory management, or remote monitoring support agreements.
Options de financement: Available through partner institutions include traditional equipment leasing structures or projectbased financing solutions tailored for large capital expenditures.

Foire aux questions (FAQ)

1. Is this rotary clinker cooler compatible with our existing kiln system?
A full engineering assessment is required. Our team reviews your existing kiln discharge housing geometry, elevation points,and material handling interfaces to design a compatible retrofit solution that minimizes disruption.Spécifications du producteur d'équipement de cimenterie

2. What is the typical impact on overall plant thermal efficiency?
Field data shows that replacing an inefficient older cooler can improve overall plant thermal efficiency by between 1% et 4%, primarily through higher secondary/tertiary air temperatures which directly lower main burner fuel requirements.

3. How does this equipment handle variations in clinker quality or granulometry?
The tumbling action of a rotary cooler is generally more forgiving than grate systems regarding fines content or slight variations in pellet size.The controlled residence time ensures even coarse particles are adequately cooled before discharge.

4. What are standard commercial terms like delivery timeframe?
For standard capacity models,the delivery period ranges from 12 months exworks after final design approval.Customengineered largecapacity units require longer lead times.Detailed project schedules are provided upon request.

5.

Laissez votre message

Écrivez votre message ici et envoyez-le-nous

Laissez votre message