Voer vervaardiger van sementaanlegtoerusting in
H1: Optimize Clinker Cooling and Heat Recovery with Advanced Grate Coolers
PYNPUNT GEDREWE OPENING
Managing the clinker cooling process presents persistent challenges that directly impact your plant’s bottom line. Inefficient cooling leads to excessive heat loss, reducing the quality of secondary heat available for kiln and raw mill operations. Unstable grate bed conditions cause erratic clinker bed permeability, resulting in highpressure fans working harder and spiking energy consumption. Perhaps most critically, unreliable equipment and frequent maintenance interventions on traditional coolers lead to unplanned downtime, disrupting the entire production chain and incurring significant costs in lost output and emergency repairs.
Are you facing rising energy costs per ton of clinker? Is your maintenance team constantly addressing grate plate wear or fan issues? Are you struggling to achieve consistent clinker quality due to uneven quenching? The solution lies in a fundamental reengineering of the clinker cooling process.
PRODUK OORSIG: Advanced Reciprocating Grate Coolers
The modern reciprocating grate cooler is engineered for precise thermal management and mechanical reliability in cement production. This equipment receives incandescent clinker from the rotary kiln discharge and systematically reduces its temperature from approximately 1400°C to an ambient temperature suitable for conveying and storage, while simultaneously recovering highgrade heat for process efficiency.
Operasionele werkvloei:
1. Beheerde verspreiding: Hot clinker is evenly distributed across the full width of the grate via a regulated feed system.
2. Stratified Cooling: Reciprocating grates transport the clinker bed horizontally while multiple controlled pressure fans force ambient air upwards through the material layer in distinct zones.
3. Efficient Heat Recovery: Hightemperature air from the hot zone is directed to the kiln as secondary air or to a calciner as tertiary air. Midtemperature air may be used for coal drying or other processes.
4. Final Quenching & Ontslag: Fully cooled clinker is discharged via a crusher onto conveyor systems for transport to storage.
Toepassingsomvang: Designed for new dryprocess cement production lines or as a retrofit replacement for older planetary or firstgeneration grate coolers. Limitations include requirement for consistent feed sizing from the kiln and are typically engineered as part of a complete kiln system upgrade.
KERNKENMERKE
Optimized Grate Plate Design | Tegniese basis: Highresistance, staggered configuration with advanced alloy casting | Bedryfsvoordeel: Creates a stable, permeable clinker bed with minimal "rooi rivier" effects, ensuring uniform air distribution | ROI impak: Reduces specific cooling air volume by up to 15%, lowering fan power consumption and improving heat recovery quality.
Modular Resistance Fan System | Tegniese basis: Independently controlled, highefficiency fans aligned with longitudinal cooling zones | Bedryfsvoordeel: Allows precise adjustment of air volume and pressure per zone based on realtime clinker conditions | ROI impak: Velddata toon a 1020% reduction in overall cooler electrical energy use versus nonmodulated systems.
Robust Drive & Raamsamestelling | Tegniese basis: Centralized lubrication system with heavyduty roller bearings and sealed drive linkages | Bedryfsvoordeel: Minimizes mechanical stress points and provides reliable, continuous movement under extreme thermal loads | ROI impak: Extends major drive component service life by an estimated 30%, reducing longterm capital spares costs.
Gevorderde prosesbeheer-integrasie | Tegniese basis: PLCbased system using inputs from pyrometers, druksensors, and kiln feed rate | Bedryfsvoordeel: Automatically adjusts grate speed and fan settings to maintain optimal bed depth and outlet temperature | ROI impak: Stabiliseer oondwerking, bydra tot 'n gedokumenteerde 13% increase in fuel efficiency through consistent secondary air temperature.
Enhanced Heat Recovery Ducting | Tegniese basis: Shortened, insulated duct paths with refractorylined junctions to minimize pressure drop and heat loss | Bedryfsvoordeel: Maximizes the enthalpy of recovered air delivered to the kiln burner hood or calciner | ROI impak: Improves overall thermal efficiency of the pyroprocessing line, directly reducing specific fuel consumption.
MEDEDINGENDE VOORDELE
| Prestasie-metriek | Bedryfstandaard (Older Grate Cooler) | Advanced Grate Cooler Solution | Voordeel (% Verbetering) |
| : | : | : | : |
| Klinker Uitlaat temperatuur | ~120°C + Omgewing | ~65°C + Omgewing | ~45% Vermindering |
| Heat Recovery Efficiency| 6570% Recovered Air Enthalpy| 7278% Recovered Air Enthalpy| ~10% Increase |
| Spesifieke kragverbruik| 79 kWh/t Clinker| 5.57 kWh/t Clinker| Tot 22% Vermindering |
| Roosterplaat Dienslewe| 1218 Maande| 2436 Maande| ~80% Toename |
| Operasionele Beskikbaarheid| ~9294% (Excluding Kiln Stops)| >97% (Excluding Kiln Stops)| >3 Persentasiepunte |
TEGNIESE SPESIFIKASIES
Kapasiteitsreeks: Engineered for kiln outputs from 2,000 TPD tot verby 12,000 TPD.
Kragvereistes: Total installed fan power varies by capacity; typical range is 500 kW 2,500 kW at supply voltages of 6.6kV or below.
Materiaalspesifikasies: Hot zone grate plates cast from highchrome alloy (2833% Kr); side liners with abrasionresistant plating; main structure in heavy carbon steel.
Fisiese afmetings: Varieer aansienlik volgens kapasiteit; voorbeeld vir 'n 5,000 TPD line includes approximate footprint of 25m (L) x 8m (W).
Omgewingsbedryfsreeks: Ontwerp vir omgewingstemperature van 20°C tot +50°C; dusttight housing maintains performance in all weather conditions.
TOEPASSINGSSCENARIO'S
Cement Plant Kiln Line Upgrade
Uitdaging: A plant operating a legacy cooler faced high fuel costs due to poor heat recovery (74%, spesifieke brandstofverbruik met ongeveer verminder 3%. Maintenance intervals extended to over 24 months for hot zone grates.
New Integrated Cement Production Line
Uitdaging: An engineering contractor required guaranteed performance data for a greenfield project where stable kiln operation from day one was critical for project financing.
Oplossing: Selection of a fulllength reciprocating grate cooler with integrated advanced process control designed specifically for the projected clinker characteristics.
Resultate:The cooler achieved guaranteed outlet temperatures within two weeks of commissioning. The stable secondary air supply contributed to kiln reaching nameplate capacity 15 dae voor skedule.
KOMMERSIËLE OORWEGINGS
Toerustingpryse is gerangskik op grond van kapasiteit (TPD) vlak:
Vlak I (7,500 TPD): Fully customized designs incorporating all advanced features for maximum lifetime ROI on largescale operations.
Optional features include upgraded hydraulic drives vs mechanical drives, premium refractory packages for ducting,and integrated condition monitoring sensors.Service packages range from basic commissioning support upto comprehensive longterm service agreements (LTSA) covering preventive maintenance,inspeksies,and parts discounts.Financing options including leasetoown structures are available through partnered financial institutions,making capital outlay manageable against operational savings.
Gereelde vrae
1. V:What level of modification is requiredto retrofit this cooler into an existing plant layout?
A.Retrofit projects are engineered on acasebycase basis.We conduct full laser scans ofthe existing structure.Designs often utilize current foundationsand footprintto minimize civil work,costing,and downtime during changeover
2.Q.How does this equipment impact overall plant thermal efficiency?
A.The primary contributionis through improved quality(enthalpy)and quantityof recovered secondary/tertiaryair.Field data consistently showsa direct correlation between efficientgrate cooler operationand reducedkilnspecificfuelconsumption
3.Q.Whatisthetypical deliverylead timefor anewcooler?
A.Forstandardcapacitymoduleslead timesrange from8to12monthsfromorderplacementincludingengineeringmanufacturingandtesting.Largecustomunitsmayrequire14+monthsAccurateproject timelinesareprovidedwithdetailedquotations
4.Q.Arethequotedperformanceguarantees backedbycontractualpenalties?
A.Yesthekeyperformanceindicators(KPI's)forclinkercoolingefficiencyoutlettemperatureandspecificpowerconsumptionarecontractuallyguaranteedwithclearlydefinedtestprotocolsandliquidateddamagesfornonperformance
5.Q.Whatisthesparepartspolicyandavailability?
A.CriticalsparepartslikegrateplatesaredesignedforinterchangeabilitywithinzonesWe maintainregionalinventoryhubsforfastshipmentofcriticalitemsto minimizeequipmentdowntime
6.Q.CanthenewcoolercontrolsystemintegratewithourexistingplantDCS?
A.ThePLCbasedcontrolsystemisdesignedwithstandardcommunicationprotocols(OPCUA.ModbusTCP/IP)ensuringseamlessintegrationintomostmodernplantwideDistributedControlSystemsforunifiedoperation
7.Q.Whattrainingisprovidedforouroperationalandmaintenancestaff?
A.Comprehensive trainingprogramsincludetheoreticalclassroom sessionsonsite duringcommissioningandhandsonpracticalworkshopsCoverageincludesnormaloperationtroubleshootingpreventivemaintenanceproceduresandsafetyprotocols